Description

 

According to specific application  scenarios,  the  company's  proton  exchange  membrane for  hydrogen  production  from  electrolytic  water  can  be  divided  into  11x  series  proton exchange  membrane  for  industrial  hydrogen  production  and  11x  W  series  proton exchange  membrane  for  hydrogen  health.Nepem  proton  exchange  membrane  for electrolytic  water  has  the  characteristics  of  high  conductvity,  low  gas  permeabllity  and high   pressure   resistance.

 

   Thickness and Basis Weight Properties

Membrane Type

Thickness(microns)(um)

Weight(g/m²)

N-115

125

246

N-117

175

345

N-1110

220

432

N-115W、N-116W、N-117W

125、150、175

246、295、345

 

   Physical and Other Properties

Physical and Other Properties

Index Parameters

Test Method

Tensile Test(23℃,50% RH)

N-11

N-11W

 

Tensile Strength(MPa)

≥28

≥28

GB/T  20042.3-2022

Tensile Modulu(MPa)

≥400

≥200

GB/T  20042.3-2022

Elongation at break(%)

≥120

≥200

GB/T  20042.3-2022

Specific Gravity

1.97

1.98

 

OtherProperties

Index Parameters

Test Method

 Conductivity²(S/cm)

≥0.100

≥0.100

GB/T  20042.3-2022

Acid Capacity³(meq/g)

1.00±0.05

1.00±0.05

GB/T  20042.3-2022


Dissolved Hydrogen Concentration
(ppb Max)

 

1000


 THNKRE, the perormance ofhydrogen   producton   can
be comparable to that of
foreign brands N11-series.

 

   Hydrolytic Propertie

Hydrolytic Properties

Index Parameters

Test Method

Water Content⁵(%)

5.0±3.0

5.0±3.0

GB/T 20042.3-2022

Water Uptake(%)

50.0±5.0

50.0±5.0

GB/T 20042.3-2022

(23℃,50% RH)Thickness Change,% increase

 

water soaked at 23℃ 50% RH

≤5

≤18

GB/T 20042.3-2022

water soaked at 100℃ 50% RH

≤15

≤30

GB/T 20042.3-2022

Linearexpansion,%increase(23℃,50% RH)

 

water soaked at 23℃ 50% RH

≤5

≤16

GB/T 20042.3-2022

water soaked at 100℃ 50% RH

≤18

≤20

GB/T 20042.3-2022

 

  Measurements taken with membrane conditioned to 23 ℃,50%RH. 
  Conductivity measurements at 23 ℃,100%RH.
  A base titration procedure measures the equivalents of sulfonic acid group in the polymer resin,and uses the measurement to calculate the acid capacity or equivalent weight of the membrane.
  Water content of membrane conditioned to 23 ℃ and 50%RH(dry weight basis).
  Water uptake from dry membrane to conditioned in water at 100℃ for l hour (dry weight basis).